SUP-PSS200 Suspended solids/ TSS/ MLSS meter

SUP-PTU200 Suspended Solids Meter based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of suspended solids and sludge concentration. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of cuspended colids and cludge concentration value. According to the usage environment, self-cleaning function can be equipped with.

Characteristics

Range: 0.1 ~ 20000 mg/L; 0.1 ~ 45000 mg/L; 0.1 ~ 120000 mg/L

Resolution: Less than ± 5% of the measured value

Pressure range: ≤0.4MPa

Power supply: AC220V±10%; 50Hz/60Hz

  • Specification

  Product  Suspended Solids (Sludge Concentration/ TSS/ MLSS) meter
  Model SUP-PSS200
 Main materials lower casing: Aluminum with powder covering
cover: PA66+GF25+FR
 Waterproof rate IP65
 Storage temperature -20~70℃
 Operation Temperature -15~60℃
 Output three-way analog output 4-20mA, response parameters and corresponding scope can be programmed Note: the maximum load is 500 ohms
 Relay three-way relay can be set up, and response parameters and response values can be programmed
 Display  128 * 64 dot matrix LCD with LED backlight
 Digital Communication MODBUS RS485 communication function, which can transmit real-time measurements
 Power Supply AC:85-500V, 50/60HZ, 5W          DC:9-36V
 Size 145*125*162mm  L*W*H
 Weight 1.35 KG

 

  • Introduction

SUP-PPS200 suspended solids meter, based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of turbidity. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of turbidity value. According to the usage environment, self-cleaning function can be equipped with. It assures the stability of data and reliability of performance; with the built-in self-diagnosis function, it can make sure the accurate data be delivered; besides, the installation and calibration is quite simple.

Pss meter

  • Description

Suspended Solids meter

Suspended Solids meter

Suspended Solids meter mlss meter

Need more information?

Contact us for more details about our boilers,solutions and services

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.